Specifications
Two-inch flange, 125 vdc, solenoid pilot actuated (SPA)
Parker Meggitt’s two-inch poppet style gas flow shutoff valve is in use on a variety of industrial gas turbine engines. Millions of field operating hours continue to prove the high reliability of Parker Meggitt design technology.
Function: Fail-safe fuel gas flow shutoff for aero-derivative gas turbine engines
Physical size: 9.95″ flange to flange, 15.19″ high
Weight: 85 pounds maximum
Flange type: 2.0″ ANSI B16.5 CL 600 raised face flanges
Line pressure: 0 to 1000 psig
Fluid temperature: 32 to 380°F
Ambient temperature: –65 to 220°F
Performance
Flow: Linear trim, 0 to 6.1 pounds/sec natural gas, Cv = 55
Leakage: ANSI class V
Operating time: 100 msec full stroke response,100 msec fail-safe closed
(de-energized)
Electrical
Solenoid: Continuous duty, 125 VDC nominal (95 to 140 VDC), 0.43
ampere at 140 VDC and –65EF
Closed position indicating switch: 125 VDC, 3-wire, SPDT
Released versions
- C329305-1
- C329305-2
- C329305-3
- C329305-4
- C329305-5